Ready for Real-time in 5 Minutes
• Quantitate gene expression
in cells--without isolating RNA
• 5 minute cell
lysis procedure
• Ideal for monitoring
siRNA-induced knockdown
• Compatible with
TaqMan® Gene Expression Assays and SYBR® Green
• qRT-PCR from
lysate equivalent to 3 cells
• Easily adapted
to high throughput analysis
Real-time quantitative RT-PCR (qRT-PCR)
is the most sensitive technique for mRNA detection and quantitation
currently available. qRT-PCR is also the preferred method for
validating array analysis results, RNA interference experiments,
and other techniques that evaluate gene expression changes.
Ambion's Cells-to-Signal Kit (patent pending)
is an improvement to the popular Cells-to-cDNA II
Kit for cell lysate preparation for direct use in real-time
qRT-PCR experiments. The kit uses a chemical lysis method to
create cell lysates in less than 5 minutes at room temperature.
The cell lysate can be used directly for RT-PCR when PCR primers
are designed to span intron-exon boundaries, bypassing RNA
isolation altogether. Lysates can be stored for future experiments.
The Cells-to-Signal procedure is highly reproducible and is
compatible with a wide variety of cell types. These improvements
result in a single-step procedure that is optimized for high
throughput analyses -- both for manual processing and on robotic
platforms.
Compatible with TaqMan Gene Expression
Assays
Applied Biosystems® pre-designed primer and probe sets for real-time
PCR are one of the most commonly used methods for measuring changes in gene
expression by qRT-PCR. The Cells-to-Signal technology is compatible with TaqMan
Gene Expression Assays (formerly known as Assays-on-Demand).
Figures 1 and 2 show data generated in one-step real-time RT-PCR using TaqMan
Gene Expression Assays for human GSK-3ß and VEG-F. In addition, the data
(Figure 2) also demonstrate that the Cells-to-Signal procedure is sensitive
enough to detect target in lysate equivalent to 3 cells.
|
Figure 1. qRT-PCR
Detection of GSK-3ß Using TaqMan® Gene
Expression Assays and Cells-to-Signal. HeLa
cells were lysed at concentrations of 1000, 200, 40,
8, and 1.6 cells/µl according to the Cells-to-Signal
lysis procedure. 6 µl of cell lysate was used
in a 20 µl one-step RT-PCR using a TaqMan Gene
Expression Assay primer and probe set specific for
GSK-3ß. |
|
Figure 2. qRT-PCR
Detection of VEG-F Using TaqMan® Gene
Expression Assays and Cells-to-Signal. HeLa
cells were lysed at concentrations of 1000, 100, 10
and 1 cells/µl according to the Cells-to-Signal
lysis procedure. 3 µl of cell lysate was used
in a 10 µl one step RT-PCR using a TaqMan Gene
Expression Assay primer and probe set specific for
VEG-F. |
Measuring siRNA Induced Knockdown
siRNA induced knockdown of gene
expression is now one of the most widely used methods to determine
gene function. Scientists at Ambion performed a study using cultured
HeLa and MCF-7 cells transfected with 3 nM of chemically synthesized
siRNA targeting GAPDH to demonstrate the effectiveness of the
Cells-to-Signal Kit for measuring knockdown of gene expression
(Figure 3). As expected, the expression levels of both GAPDH
was down-regulated by more than 80% compared to cells transfected
with a scrambled control, while the expression of 18S rRNA was
unchanged.
|
|
|
Figure 3. Cells-to-Signal is
Ideal for Measuring siRNA Induced Knockdown of Gene
Expression. HeLa
cells were plated in a 24 well plate at 30,000 cells/well.
Cells were transfected with either a scrambled control
(green) or with an siRNA to GAPDH (blue) at a concentration
of 30 nM. After 48 hours, the cells were harvested
and lysed in the Cells-to-Signal Lysis Buffer in a
final volume of 500 µl. 3 µl of the cell
lysate was used in one step RT-PCR, using a TaqMan® primer
and probe set for GAPDH. GAPDH signals were normalized
using 18S as an internal control (pink).
|
Ideal for High Throughput
The quick and simple Cells-to-Signal
protocol can be easily adapted to a 96 or 384 well format, thus
enabling the simultaneous analyses of multiple cell samples.
The protocol will afford excellent reproducibility as seen in
Figure 4 where VEG-F and GAPDH expression levels were determined
in HeLa and MCF-7 cells grown in a 96 well plate.
|
|
|
Figure 4. Measurement
of GAPDH and VEG-F Expression Levels
in a 96 well Format Using Cells-to-Signal. 3000 HeLa or MCF-7 cells were plated in 48 wells each of the same 96 well plate. Cells were grown for 24 hours, media was removed, and cells were washed once with 200 µl of 1X PBS. 200 µl of the Cells-to-Signal Lysis Buffer were added to the cells, and the plates were incubated for 5 min at room temperature. 3 µl of lysate were used in a 10 µl one-step RT-PCR using TaqMan® Gene Expression Assay for GAPDH or VEG-F. The two amplification curves on the left are for GAPDH, and the curves on the right are for VEG-F. The amplification curves in red and dark green were generated using HeLa cell lysate. The amplification curves in purple and light green were generated using lysate prepared from MCF-7 cells.
|
SYBR® Green Detection
Real-time detection of PCR products
using SYBR Green is a commonly used method to quantitate gene
expression by RT-PCR. Though SYBR Green detection requires more
optimization than other real-time PCR detection
techniques, it is economical and can be carried out on virtually any real-time
detection platform. The Cells-to-Signal Kit is compatible with SYBR Green detection
used with two-step RT-PCR.
Long-term Stability
When working with multiple cell
samples, it is not always feasible to simultaneously process
them all. Likewise, cell lysates may be needed at a later stage
for repeating prior experiments or for quantitating the expression
of different genes from the same sample. Lysates made with the
Cells-to-Signal Kit can be safely stored at -20°C for
two months or longer without RNA degradation (Figure 5).
|
Figure 5. Stability
of Cells-to-Signal Lysates. HeLa
cells were lysed at a concentration of 1000 cells/µl
using the Cells-to-Signal Lysis Buffer. 100 µl
aliquots of the lysate were stored for two months at -80ºC
or -20ºC. Ambion's RNAqueous® Kit
was then used to isolate total RNA from each aliquot
along with an aliquot of lysate that was freshly prepared
(not stored). RNA isolated from an equivalent number
of cells processed using the RNAqueous procedure is
shown on the far right. The RNA samples were analyzed
on an RNA LabChip® using the Agilent
2100 bioanalyzer and show rRNA bands. |
Complete Kit for Cell Lysis and cDNA Synthesis
The Cells-to-Signal Kits contain
reagents for 30 or 100 reverse transcription reactions, including
M-MLV RT, oligo(dT)18 primers, and random
decamer primers. Up to 5 x 104 cells per reaction
can be used for the lysis step; up to 30% of the RT reaction
volume can consist of cell lysate. Ambion scientists have used
the Cells-to-Signal Kit with cell lines including HeLa, HeLa
S3, 293, A549, MCF-7, K562, SKNAS and NHDF-neo cells, and we
continue to test other cell types. The kit contains a positive
control RNA and complementary primers for optimizing the procedure.
This control can be added with the lysis solution to monitor
the efficiency of the procedure. SuperTaq Polymerase
is available separately.
back