Products Documents
MEGAscript® High Yield Transcription Kit

To See Pricing -->



(Only those countries served by Ambion are listed)

Cat#
Product Name
Size
AM1330 MEGAscript® SP6 Kit 40 rxns
NEW! AM1330M MEGAscript® SP6 Kit w/Manual 40 rxns
AM1338 MEGAscript® T3 Kit 40 rxns
NEW! AM1338M MEGAscript® T3 Kit w/Manual 40 rxns
AM1334 MEGAscript® T7 Kit 40 rxns
NEW! AM1334M MEGAscript® T7 Kit w/Manual 40 rxns
AM1333 MEGAscript® T7 Kit 25 rxns
NEW! AM1333M MEGAscript® T7 Kit w/Manual 25 rxns
AMB1334-5 5X MEGAscript® T7 Kit 200 rxns
For Research Use Only. Not for use in diagnostic procedures.
  • Exclusive ultra high yield technology is fast - 2 hour reaction time

  • Amplifies aRNA for gene array analysis

  • Efficiently incorporates many modified nucleotides

  • Kits specific for templates with T7, T3 and SP6 RNA polymerase promoters

Transcription reactions with MEGAscript® High Yield Transcription Kits use novel reaction conditions and Ambion's patented, high yield technology that allow the synthesis of 10 to 50 times the amount of RNA produced by conventional transcription reactions. Each DNA template is copied hundreds of times, allowing the production of milligram quantities of RNA from a single kit.

The yield of MEGAscript Kit reactions depends both on the polymerase and the template being transcribed, but a typical 20 µl MEGAscript reaction with 1 µg of the pTRI-Xef-1alpha control template will yield over 100 µg of transcript. The versatility of the MEGAscript kit allows the manipulation of the reactions to include specialized reagents such as modified nucleotides, cap analog or additional polymerase. The RNA synthesized from a MEGAscript reaction is suitable for many applications including in vitro translation, microinjection, ribozyme studies, RNA structural analysis, nonisotopic probes, low specific activity probes, RNAi analysis, RNA vaccines and aRNA amplification.

The MEGAscript Kit can be used to overcome a primary limitation of gene profiling with gene arrays. Gene profiling using gene arrays requires up to 100 µg of total RNA or 5 µg of poly(A) RNA for each hybridization. It is often impossible to obtain enough RNA for this application from small samples such as cancer cell lines, excised surgical tissues, or cells obtained from Laser Capture Microdissection. MEGAscript has been used extensively to solve this problem through the amplification of low-abundance messages from samples where RNA is limiting (see citations at right). RNA is isolated from the tissue, reverse transcribed, and amplified via antisense RNA amplification using the MEGAscript Kit.

The MessageAmp™ II Kit, developed especially for the amplification of cRNA prior to array analysis, is powered by MEGAscript technology. MessageAmp II can amplify as little as 100 ng of input RNA in a single round for GeneChip® analysis. A rationally engineered MMLV RT, ArrayScript™, is provided in the kit to maximize yields of full-length cDNA. These features result in high labeling efficiency, yielding consistently high percent present-calls and low 3'/5' ratios in GeneChip analysis. This procedure is compatible with biotin, cyanine dye (Perkin Elmer), and Cy™Dye (Amersham Biosciences) labeling either during or after cRNA amplification.

To purify in vitro transcription products from free nucleotides, buffer components, and enzymes, Ambion recommends using the MEGAclear™ Purification Kit. MEGAclear is a fast, convenient, solid phase clean up method that is ideal for purifying large scale transcription reactions.

In some situations, it may be necessary to completely remove the plasmid DNA template after RNA synthesis. For example, it is desirable to eliminate any residual DNA before using the nascent RNA as a standard for RT-PCR or in microinjection experiments. Ambion strongly recommends TURBO DNase™ for this task. TURBO DNase is 63-fold more effective than standard DNase I in clearing DNA from in vitro transcription reactions, such as MEGAscript or mMessage mMachine™, as measured by real-time RT-PCR.

Trademarks, Patents, Licensing

RELATED PRODUCTS
MEGAclear™
MessageAmp™ II aRNA Amplification Kits
RNaseZap® RNase Decontamination Solution
TURBO™ DNase

RELATED DOCUMENTS
Protocols and Manuals
MEGAscript™ Kit Instruction Manual [go]
Supplemental Protocols
Protocol for Synthesizing Biotinylated aRNA [go]
Citations
MSDSs
Molecular Biology Tables
Phage Polymerase Promoters: Minimal Sequence Requirements [go]
TechNotes Articles
Yield isn’t Everything in a High Yield Transcription Kit! [read]
General Articles
In Vitro Transcription: The Basics [go]
Technical Bulletins
In Vitro Synthesis of RNA [go]
Practical Tips for In Vitro Transcription [go]
Figures
[full-size]

MEGAscript® T7 Kit

[full-size]

Schematic of aRNA synthesis.

[full-size]

Transcription of Long Templates with the MEGAscript™ Kit and a Competitor's Kit.

[full-size]

Effect of Template Size on Yield of MEGAscript™ Reactions.

[full-size]

MEGAscript™ Yield Comparison.

[full-size]

RNA Products From Two Transcription Systems.

[full-size]

Mass Amounts of RNA Transcripts Produced by Two Distinct Transcription Systems.

[full-size]

Electropherogram of RNA Transcripts of Different Sizes From Two Transcription Systems.

 
Search Our Catalog Search Hints
Search by Catalog Number or Product Name:
 
Home | Products | Technical Resources | What's New | About Us | Contact Us
Advanced Search | Site Map | Privacy | Trademarks/Legal | Web Feedback | Jobs
© Applied Biosystems. All rights reserved.